Scada Software
Final version: 5.1.6(02/26/2014):- Numericupdown Thousand Separator was added.
- 46 different type SQL query added for reporting tools.
- Print document function was update, Print screen command added.
- Plc communication error function added.
- Decimal place added for scale function.
- Alternative Ip address added for Redundant and all plc communication driver.
The FIX32 SCADA system (originally provided by Intellution and latterly by GE Intelligent Platforms) and the Mitsubishi MX32 OEM version have not been developed since 1999 but are still widely used by manufacturers globally. All of these blocks exhist within the SCADA server's Process Database (PDB) and are what you call 'internal'. The block you might be interested in (for both iFIX and FIX32) is the boolean block. It looks at values of other blocks, and if your boolean expression is true, it passes a 1 to the next block in the chain. The MatrikonOPC Server for Intellution FIX and iFIX is a highly reliable OPC server that enables data interchange between OPC clients and the Intellution HMI system. The server provides read and write access to all database tags and fields. Device Software: Intellution FIX32 software (version 6.x.x or greater), or other EDA compatible system. FIX32 is a really old package from Intellution; became iFIX when GE bought out Intellution. The software came out in the 80s or 90s. We have it on a pair of NT4 machines, controlling some equally old Siemens TI505 PLC hardware. DH+ OPC Server with Intellution Fix32 under Windows NT version X.xx, March 17, 2000 2 of 2 Installing and Configuring the 5136-SD card 1. Turn off your PC and install the 5136-SD interface card following the instructions for cabling, termination, etc. Found in the 5136-SD User's Guide. Install Intellution's FIX32 software.
5.1.2(11/25/2013): Multiple screen designer update, many function added.
5.1.1(10/08/2013): Redundant working style was added. Please visit our blog for more information. http://www.scadasoftware.net/redundant/
5.0.4(03/20/2013): Scada object Backcolor, Forecolor, Enable, Visible and Text property compare method added. Omron Fins Ethernet protocol added. Webserver with password protection or without protection select function added.
Intellution Fix32 Software Install
5.0.0(02/21/2013): Please visit our blog for more information. http://www.scadasoftware.net/wintr-scada-version-5-0-0-features/
- Alarms and Warnings can be defined for process values. When alarm or warning occurred, it can be monitored in the Screen real time and informed to E-Mail and SMS recipients.
- Easily creates detailed Reports from historical datas and saves them in Excel or PDF format..
- With Recipe, previously saved values for the tags are send to the devices by one click.
- For creating advanced Screen interfaces, WinTr contains; Symbol Factory software which contains 4000 industrial symbol in 60 category, Dundas's elegant Chart(Real Time, Historical, Pie, Line, Bar, 3D) and Gauge(Circular, Numeric, Linear, Knob) objects,
- Microsoft .NET Framework's Button, CheckBox, RadioButton, Combobox, NumericUpDown, Horizantal ScroollBar, Vertical ScrollBar, ProgressBar, Datagridview, DateTimePicker, TabControl, GroupBox, PictureBox, TextBox, Toolstrip objects.
- Unlimited flexibility withVisual Basic and C# scripting.
- Uses Microsoft SQL Serverfor(2005,2008,2012) databases. Limited 4gb, unlimited table and each table limited 950 Tags.
- With Server-Client option WinTr stations can be run synchronously through Internet and Screens can be monitored on remote computers by web browsers such as Internet explorer.
- WinTr Scada Software is sold with 3 years free upgrade warranty.
- WinTr Scada Software development is free, runtime and development are sold together.
- WinTr Scada Software users are given indefinite free technical support. (By email other than Turkey)
- You buy WinTr Scada Software license when you deliver your project to your customer after the completing your project. (With Demo license only first symbol of symbol factory can be used.)
- Many other scada softwares are not developed in .NET platform. .NET platform born in 2003. However WinTr Software is developed at .NET 2008. Thus development is very easy. Moreover it is compatible with Windows 7 and other operating systems that will be released. New Operating systems are released .NET framework compatible.
- Many .NET objects that can not be found other SCADAs presented in WinTR. Thus your project get out of Windows 95 look and gets Vista apperiance.
- We are taking to your service 2009 years award winning chart object dundas chart and gauge. WinTr is the only scada software that uses this variation and visuality.
- Reaching Scada variables is very easy with SQL Input/Output tags. You can reach easily with other programs that you developed or internet browsers or excel. Many scada software export data to excel. WinTr can do this too. But the method mentioned here is different. In this method, scada never reaches excel. Excel reaches to scada via excel macro.
- VB and C# scripts are work completely different. Scada softwares has a restrictions at script functions. However Wintr has no restrictions you can perform many operations by writing scripts almost as if developing program on .NET platform.
- It is possible to reach and modify scada informations other than the scada tags with scripts. When such needs occur we provide information our customers freely. We develop needed scripts for our customers some case free some case with fee.
- Scripts are compiled once at first then saved as .Net DLL. Then runs directly. Thus they run faster. Even huge amount operations can run very fast in the script.
- At many scada software, the function number which can be run by a button or other object are limited. However 256 function can be run with WinTr Scada Software Also you can trigger this functions when alarm occured or gone.
- Thousands WinTr scada may establish full or restricted access to each other via server and client functionality.
- Can be connected to automation devices via S7 MPI, PPI, Profinet, Host-Link and modbus RTU without OPC server.
- E-mail and SMS sent when specified conditions occur.
- You can create many different recipe algorithms with categorized recipe.
- Real time data monitoring and control can be done with real time working feature which achieved version 2.0.0
- First going Runtime mode at high number tags may be slow. Then all objects connects each other as interrupt and only works when values changed. Thus you can develop high tag count projects for slow computers. High number means 20000 tag and upper.
- Beside many image file you can use animated gif images in scada pages.
- We present all of this excelent features with low price.
Buy now!
You Tube:How to make first scada project ? , Scada general features , How to make reports in scada? , How to get print out from the scada? , How to set scada as server & client? , How to use web server feature of scada?
Model & Price
Function | Starter | Basic | Proffesional | Ultimate |
Development & Runtime | X | X | X | X |
Realtime & Historical Trend | X | X | X | X |
Gauge | X | X | X | X |
.Net Component Object | X | X | X | X |
Cutaway | X | X | X | X |
Symbol Factory | X | X | X | X |
Alarm Management | X | X | X | X |
Vb & C# Script | X | X | X | X |
Database Support (4 gb.) | X | X | X | X |
Opc Client | X | X | X | X |
Plc Communication Driver | X | X | X | |
Recipe | X | X | X | |
Reporting | X | X | ||
Sms | X | X | ||
X | X | |||
Printing (Barcode) | X | X | ||
Barcode Reader | X | X | ||
Excel Support | X | X | ||
Pdf Support | X | X | ||
WinTr Server & Redundant | X | |||
Web Server (Ready Only) | X | |||
EventView | X | |||
ActiveX, Dll, .Net component Support | X |
Intellution Fix 32 Software Download
Tag | Starter | Basic | Professional | Ultimate |
64 | 128 Usd. | 228 Usd. | 478 Usd. | 728 Usd. |
128 | 256 Usd. | 356 Usd. | 606 Usd. | 856 Usd. |
256 | 512 Usd. | 612 Usd. | 862 Usd. | 1112 Usd. |
512 | 768 Usd. | 868 Usd. | 1118 Usd. | 1368 Usd. |
1024 | 1024 Usd. | 1124 Usd. | 1374 Usd. | 1624 Usd. |
2048 | 2048 Usd. | 2148 Usd. | 2398 Usd. | 2648 Usd. |
65534 | 4096 Usd. | 4196 Usd. | 4446 Usd. | 4696 Usd. |
Dongle price 25 Usd.
- Upgrading price is amount of the difference between new licence and current licence. With new version licence upgrade is processed by the application that arranged for you. These application's price is 50 usd.
- You need a two identical(same configuration) licence for fully backed up working of two computer(redundant). Client-Server architecture is different than Redundant system. Client reads tag value from the server. The 64 Tag client can read all values of 65534 tag server. On the client side tags which read from server are considered as ‘internal' tag. On the other hand redundant system works one on one synchronize. If one computer disabled all operation taken on the other computer.